智颖汇ECC200网络控制器 - 产品展示图
智颖汇ECC200网络控制器 - 产品展示图

ECC200 Network Controller

The ECC200 Network Controller is a member of the BEATs product family. It is a compact, high-performance embedded controller equipped with a dual-core processor and expanded memory capacity. Supporting a variety of field protocols simultaneously, it facilitates seamless connection to remote I/O modules and on-site controllers.
Integrated with functions including alarm management, scheduling, trend logging, event management and network management, the controller complies with BACnet and B-BC standards and requirements. It serves as an ideal solution for distributed control and management in building automation systems.
FEEDBACK CONTACT US
Product Detail

Product Features

  • Complies with BACnet standard; functions as a BACnet Router device with BBMD capability.

  • Dual-core high-performance processor:

    • Arm Cortex-A9: 800 MHz

    • Arm Cortex-M4: 227 MHz

  • Operating System: LINUX / RTOS

  • System real-time clock

  • Random Access Memory (RAM): 1 GB

  • Flash Memory: 4 GB

  • Two Ethernet ports supporting BACnet IP protocol

  • Three fully isolated RS485 channels, compatible with BACnet MS/TP or Modbus RTU protocol (user-configurable)

  • BACnet MS/TP communication baud rate support: 9.6, 19.2, 38.4, 76.8, 115.2 Kbps

  • Modbus RTU communication baud rate support: 4.8, 9.6 Kbps


Specifications

Product Type网络控制器(DDC控制器)
Communication InterfaceEthernet / RS485
Communication ProtocolBACnet/IP, Modbus TCP/RTU, per project
I/O CapacityPer project (expandable I/O modules)
Power SupplyAC 220V / DC 24V, refer to product specifications
MountingDIN rail / Control panel mounting
ProgrammingGraphical / Logic programming
Typical ApplicationsBuilding automation, HVAC control, energy management

Note: Specifications are subject to product datasheets and project configuration. Contact Zhiyinghui Technical Team for detailed specs.

Related Technical Articles

Application Scenarios & Selection Guide

ScenarioMonitoring/Control NeedRecommended Config
Commercial Building BASHVAC, lighting, plumbing centralized monitoringBACnet/IP master, I/O expansion, graphical programming
Hotel Building ControlGuest floor AC, fresh air, lighting interlockBACnet/IP, multi I/O expansion, schedule control
Hospital Building ControlCleanroom HVAC, ventilation, medical gas monitoringBACnet/IP, redundant communication, alarm management
Data Center EnvironmentalPrecision AC, fresh air, leak detection interlockModbus TCP/BACnet, multi-protocol gateway

Above are typical scenario recommendations. For specific selection, please contact Zhiyinghui Technical Team for professional advice.