智颖汇Air Quality系列二氧化碳变送器产品展示图
智颖汇Air Quality系列二氧化碳变送器产品展示图

Duct CO₂ Sensor

This type of sensor is a transmitter specially designed for intelligent buildings and other places where carbon dioxide concentration detection is required. It is applied to the control of intelligent ventilation systems, and plays an excellent balancing role in energy conservation and indoor air quality improvement.
It is used in ventilation and air conditioning equipment for the following applications:
Commercial complex buildings
Hotels, cinemas and museums
Underground parking lots
FEEDBACK CONTACT US
Product Detail

Product Features

  • High-precision components with pyroelectric infrared module

  • Fast and simple installation method

  • Wall-mounted and duct-mounted types available

  • Adjustable insertion depth

  • Multiple output modes and jumper-selectable options

  • AC/DC power supply selectable

  • IP65 enclosure rating (duct-mounted type)

  • ABC automatic calibration


Product Performance

SpecificationDetails
Operating Voltage24 VAC/VDC
Signal Output420 mA or 010 V (jumper-selectable) or Modbus RS485
Measuring Range0–2000 ppm (standard), 0–5000 ppm (optional), other ranges available on request
Installation MethodWall-mounted and duct-mounted
Ambient LightOptional
Terminal Block MaterialCopper
Housing MaterialABS+PC
Accuracy Error±40 ppm or ±3% of reading (whichever is greater)
Warm-up Time<1 min (full-scale stabilization <15 min)
Calibration FunctionBuilt-in ambient calibration function (ABC)
Probe Operating Temperature-25 ~ 50℃
Operating Environment-10 ~ 50℃, 0–95% RH (non-condensing)


Specifications

MeasurementCarbon Dioxide (CO₂) concentration
Sensor TypeNDIR infrared sensor (typical)
Output Signal0-10V / 4-20mA / RS485 (Modbus RTU), optional display
Power SupplyDC 24V (typical), refer to product specifications
MountingWall-mount / Duct-mount options
Measuring RangePer project (typical 0-2000ppm/0-5000ppm)
Typical ApplicationsIAQ monitoring, fresh air control, offices, schools

Note: Specifications are subject to product datasheets and project configuration. Contact Zhiyinghui Technical Team for detailed specs.

Related Technical Articles

Application Scenarios & Selection Guide

ScenarioMonitoring/Control NeedRecommended Config
ClassroomCO2 monitoring for fresh air regulation and student focusWall-mount, 0-10V/4-20mA, fresh air linkage
Meeting RoomAuto increase fresh air when CO2 rises in crowded spacesWall-mount, RS485/Modbus, BMS integration
Hospital WardWard air quality monitoring, infection preventionWall-mount, 4-20mA, central nurse station monitoring
Open OfficeCO2 monitoring in open-plan areas for comfortWall-mount, 0-10V, VAV linkage
Gym/Fitness CenterCO2 monitoring during high-intensity exerciseWall-mount, wide range, 4-20mA

Above are typical scenario recommendations. For specific selection, please contact Zhiyinghui Technical Team for professional advice.